Program Overview
This webcast showcases footage from the May 4, 2011 symposium Innovation, Evolution and Revolution in Defibrillation Therapy. This activity features international experts discussing the goal to make cardiac rhythm management safer and more effective for patients. Chairman Douglas P. Zipes, MD, FHRS leads the faculty in lively discussions to address enhancements to improve ICD implantation and outcomes.
Educational Objectives
Following completion of this activity, participants should be better able to:
- Employ advances in electrical therapy to terminate life-threatening ventricular arrhythmias
- Discuss device implantation techniques that avoid complications of vascular access
- Choose the appropriate device to manage patients at high risk for arrhythmic death
Date of Release: June 8, 2011
Term of Approval: June 7, 2012
Target Audience
This activity has been designed to meet the educational needs of:
- Electrophysiologists (EP)
- EP Fellows
- EP Lab Staff
- Nurses
- Nurse Practitioners
- Physician Assistants
- Other allied health professionals involved in the care of patients with cardiac arrhythmias
Faculty
Douglas P. Zipes, MD, FHRS—Chairman
Indiana University School of Medicine
Indiana, IN
Martin C. Burke, DO
University of Chicago Medical Center
Chicago, IL
Ian G. Crozier, MBChB, MD
USC University Hospital
Michael R. Gold, MD, Ph.D.
Medical University of South Carolina
Charleston, SC
Disclosure of Conflicts of Interest
Postgraduate Institute for Medicine (PIM) assesses conflict of interest with its instructors, planners, managers and other individuals who are in a position to control the content of CME activities. All relevant conflicts of interest that are identified are thoroughly vetted by PIM for fair balance, scientific objectivity of studies utilized in this activity, and patient care recommendations. PIM is committed to providing its learners with high quality CME activities and related materials that promote improve¬ments or quality in healthcare and not a specific proprietary business interest of a commercial interest.
The faculty reported the following financial relationships or relationships to products or devices they or their spouse/life partner have with commercial interests related to the content of this CME activity:
- Douglas P. Zipes, MD, FHRS—Chairman
No financial relationships or relationships to products or devices with any commercial interest related to the content of this activity of any amount during the past 12 months.
- Martin C. Burke, DO
Receipt of intellectual property rights/Patent holder: AJ Medical Devices; Consulting fees: AJ Medical Devices, Cameron Health; Contracted research: AJ Medical Devices, Boston Scientific Corporation, Cameron Health, Medtronic, Inc., St. Jude Medical, Inc.
- Ian G. Crozier, MDChB, MD
Contracted research: Cameron Health
- Michael R. Gold, MD, Ph.D.
Consulting fees: Boston Scientific Corporation, Medtronic Inc., Sorin Group, St. Jude Medical, Inc.; Contracted research: Boston Scientific Corporation, Medtronic, Inc. Sorin Group, St. Jude Medical, Inc.
The planners and managers reported the following financial relationships or relationships to products or devices they or their spouse/life partner have with commercial interests related to the content of this CME activity: The following PIM planners and managers: Jan Hixon, RN, BSN, MA, Trace Hutchison, PharmD, Julia Kimball, RN, BSN, Samantha Mattiucci, PharmD, Jan Schultz, RN, MSN, CCMEP, and Patricia Staples, MSN, NP-C, CCRN hereby state that they or their spouse/life partner do not have any financial relationships or relationships to products or devices with any commercial interest related to the content of this activity of any amount during the past 12 months. Medtelligence, LLC: Ben Caref, PhD, Pamela Clark, BA - No financial relationships or relationships to products or devices with any commercial interest related to the content of this activity of any amount during the past 12 months. Heart Rhythm Society: Cynthia R. Roller, BA and Zelda Gilliam, BS – No financial relationships or relationships to products or devices with any commercial interest related to the content of this activity of any amount during the past 12 months.
Presentations
- Welcome and Introductions
Douglas P. Zipes, MD—Chairman
- Do all ICDs Have to Pace?
Martin C. Burke, DO
- Has Tachycardia Discrimination Improved?
Michael R. Gold, MD, PhD
- What's the Solution?
Ian G. Crozier, MBChB, MD
- Case Presentation and Discussion
Martin C. Burke, DO
Ian G. Crozier, MBChB, MD
Michael R. Gold, MD, PhD
Interviews
- Use of Pacing in ICD Applications
Douglas P. Zipes, MD & Martin C. Burke, DO
- Subcutaneous Implantable Cardioverter Defibrillator
Douglas P. Zipes, MD & Ian G. Crozier, MBChB, MD
Physician Continuing Education Accreditation Statement
This activity has been planned and implemented in accordance with the Essential Areas and policies of the Accreditation Council for Continuing Medical Education through the joint sponsorship of Postgraduate Institute for Medicine and Medtelligence, LLC. The Postgraduate Institute for Medicine is accredited by the ACCME to provide continuing medical education for physicians.
Credit Designation
The Postgraduate Institute for Medicine designates this enduring activity for a maximum of 2.0 AMA PRA Category 1 Credit(s)™. Physicians should claim only the credit commensurate with the extent of their participation in the activity.
Acknowledgement of Commercial Support
This activity is supported by an independent educational grant from Cameron Health.
Acknowledgement of Co-Sponsorship
This activity is jointly sponsored by Postgraduate Institute for Medicine and Medtelligence, LLC. This activity is Co-Sponsored by the Heart Rhythm Society
Disclosure of Unlabeled Use
This educational activity may contain discussion of published and/or investigational uses of agents that are not indicated by the FDA. Postgraduate Institute for Medicine (PIM), Medtelligence, LLC, the Heart Rhythm Society (HRS), and Cameron Health do not recommend the use of any agent outside of the labeled indications.
The opinions expressed in the educational activity are those of the faculty and do not necessarily represent the views of PIM, Medtelligence, LLC, HRS, and Cameron Health. Please refer to the official prescribing information for each product for discussion of approved indications, contraindications, and warnings.
Disclaimer
Participants have an implied responsibility to use the newly acquired information to enhance patient outcomes and their own professional development. The information presented in this activity is not meant to serve as a guideline for patient management. Any procedures, medications, or other courses of diagnosis or treatment discussed or suggested in this activity should not be used by clinicians without evaluation of their patient’s conditions and possible contraindications on dangers in use, review of any applicable manufacturer’s product information, and comparison with recommendations of other authorities.
Participate in Activity
Method of Participation and Request for Credit
There are no fees for participating and receiving CME credit for this activity. During the period June 8, 2011 through June 7, 2012 participants must read the learning objectives and faculty disclosures and study the educational activity. PIM supports Green CME by offering your Request for Credit online. If you wish to receive acknowledgment for completing this activity, please complete the post-test and evaluation on www.cmeuniversity.com. On the navigation menu, click on “Find Post-test/Evaluation by Course” and search by Course ID 8243. Upon registering and successfully completing the post-test with a score of 70 percentor better and the activity evaluation, your certificate will be made available immediately. Processing credit requests online will reduce the amount of paper used by nearly 100,000 sheets per year.
Date of Release: June 8, 2011
Term of Approval: June 7, 2012
Required Hardware and Software
- Computer Screen with USB Drive Screen resolution of 1024x786 or larger
- Sound card and speakers/headphones
- Operating System Requirement: Windows Vista; Windows XP Service Pack 2, Windows 7 Intel® Pentium® III 450MHz or faster processor (or equivalent) 128MB or RAM Mac OS Apple Mac OS X 10.4.8 or above Intel Core TM Duo 1.83GHz or faster processor 128MB of RAM Plug-in
- Microsoft Silverlight 3 To download Microsoft Silverlight, please visit: http://www.microsoft.com/getsilverlight. If you do not have administrative rights to install browser plug-ins please contact your system administrator for assistance.
Copyright © Heart Rhythm Society 2011